SE_SUBBOTwin — Vertical Incidence & Sub-Bottom Profiler Time-Series Viewer

SE_SUBBOTwin (code/SE/SE_SUBBOTwin.c, code/SE/SE_SUBBOTwin.h) implements the "Vertical Incidence Time Series Viewer" (sub_window[SUBBOT_OFFSET .. SUBBOT_OFFSET + 15], where SUBBOT_OFFSET = 76) in swathed. Authored by John E. Hughes Clarke (January 2000) with manual bottom-repicking additions by Jonathan Beaudoin (November 2007), it provides a dedicated seismic/echogram waterfall, full-waveform trace inspector, 1D FFT spectral filter, and bottom-tracker editor for single-beam / dual-frequency normal-incidence and chirp sub-bottom profilers (e.g., Knudsen 320B/320M, Simrad EA500, and Kongsberg SBP120).


Window Architecture & Controls (sub_window[76..91])

Launched automatically when clicking the ss icon (icon_window[7]) on a Knudsen_320 dataset (or via -sub), view_subbottom_box() creates top-level form sub_window[76] (1025 × 820 px) containing:

Waterfall, Trace, and Spectral Windows

Window Dimensions Function Description
sub_window[77] (+1) 600 × 200 load_deci() Decimated 600-Ping Echogram Overview: Displays 600 consecutive pings (NO_SUB_SWATHS = 600) across the full recorded depth window (top_depth to bot_depth), marking heave (RED), tide (BLUE), and active bottom picks (GREEN).
sub_window[78] (+2) 600 × 450 load_orig() Full-Resolution Zoomed Echogram: Displays a vertically zoomed window (zoom_height samples) across the 600 pings, either in true depth (SHOW_BY_DEPTH) or aligned relative to the bottom pick (SHOW_BY_TRACE).
sub_window[79] (+3) 400 × 70 plot_info() Ping Metadata Header: Displays ping number, date/time (j_time), pulse length (pulse_length), frequency, gain (Rx_gain), and sample interval (sample_interval) for selected_sub_ping.
sub_window[80] (+4) 400 × 125 plot_profile() Full-Range Single-Ping Trace: Plots the complete amplitude/waveform trace (data[] or data_16[]/data_32[]/data_float[]) for selected_sub_ping, marking the current bottom pick in RED.
sub_window[81] (+5) 400 × 125 plot_profile() Zoomed 8-bit Single-Ping Trace: Plots the trace within the zoom window alongside the smoothed first-difference derivative used for bottom picking.
sub_window[87] (+11) 400 × 125 plot_fft() FFT Power Spectrum & Bandpass Filter: Plots the 4096-point real/imaginary FFT amplitude spectrum (0 to Nyquist kHz) of selected_sub_ping, with interactive frequency cutoff markers (filter_freq[0..3]).
sub_window[88] (+12) 400 × 125 plot_profile() 16-bit / Full-Waveform Zoom Trace: Plots signed bipolar or envelope 16-bit/32-bit/float traces (data_16, data_32, data_float) and filtered time-domain waveforms (filt_trace).

Interactive Sliders (sub_window[82..85]) & Buttons (button_window[9..14])

  • Bottom-Picking Sliders (sub_window[82..85]):
    • sub_window[82] (Pick Thresh %): Amplitude threshold percentage (pick_thresh, 0–100% of trace max).
    • sub_window[83] (Pick Window): Derivative smoothing window length (pick_win, 1–50 samples).
    • sub_window[84] (Pick Thresh % [deriv]): Derivative threshold percentage (ofwhich, 0–100%).
    • sub_window[85] (Min. Pick Depth): Minimum blanking depth (min_pick_depth) above which echoes are ignored.
  • Control Buttons (button_window[SUBBOT_BUTT_OFFSET + 0..5]):
    • 0 (ByDepth / ByTrace): Toggles sub_plot_type between true depth and bottom-flattened display.
    • 1 (Marks / NoMarks): Toggles heave, tide, and bottom-pick tracking overlays (mark_heave).
    • 2 (HF / LF): Switches between High-Frequency (CHANNEL_1, .sub Channel 0) and Low-Frequency (CHANNEL_2, .sub Channel 1) transducer channels (which_channel).
    • 3 (orig. / repick): Toggles between original recorded bottom depths (orig_depth[]) and newly repicked depths (new_depth[]).
    • 4 (RePickAll): Calls repickall() to run automated threshold/derivative bottom picking (pick_trace()) across all 600 loaded pings.
    • 5 (Write): Calls write_out_new_picks() to write updated observedDepth and race_track two-way travel times directly back into the .merged file.

Interactive Workflow (manage_SUBBOTTOM_events)

  • Left-click in sub_window[77] or [78]: Selects selected_sub_ping and updates the single-ping trace and FFT spectrum plots (calc_sub_fft()).
  • Middle-click in sub_window[77]: Centers the vertical zoom window (sub_window[78]) at the clicked depth.
  • Right-click in sub_window[78]: Manually sets new_depth[selected_sub_ping] to the clicked sample depth (JDB, Nov 2007) for surgical correction of bottom-tracking dropouts.
  • w key in sub_window[78]: Immediately writes modified bottom picks to the .merged file (write_out_new_picks()) and reloads the 600-ping buffer.